Classifying Continuous and Pulsed Solar Simulators with Portable Spectroradiometers

Spectral Evolution spectroradiometers provide accurate, affordable solar simulator measurement for validating the classification of any commercial continuous or pulsed solar simulators. They are ideal for  testing solar simulators for spectral match, uniformity, and stability. 

SR-1901 Portable Spectroradiometer for Testing and Classifying Continuous Solar Simulators

Spectral Evolution provides accurate, affordable spectroradiometers for testing, measuring, and classifying continuous solar simulators.

Rapid and accurate measurement of electrical power output and related characteristics of PV cells, modules, and panels is critical to solar manufacturers to ensure that their products will perform to promised levels during their outdoor life. Solar simulators are used to test the cells, modules, and panels under a set of standardized conditions. The solar simulators mimic the natural sunlight that the panels will see when installed. The solar simulators themselves are tested to be sure they meet ASTM and IEC standards for three areas: spectral match, spatial uniformity, and temporal stability.

Spectral match classifies a solar simulator based on the amount of light (irradiance) it outputs and assigns a Class A, B, or C status based on performance measurements in wavelengths from 400-1100nm. Uniformity measures the irradiance at different point in the area covered by the simulator. Consistent output must be measured at different points. Temporal stability measures performance over time.

SR-1901PT Portable Spectroradiometer for Testing and Classifying Pulsed Solar Simulators

In solar cell, module, and panel manufacturing there is a need to classify pulsed solar simulators for testing and verifying panel performance. The SR-1901PT spectroradiometer is ideal for quantification of pulsed solar simulators as part of a manufacturer’s quality control process.

Pulsed solar simulators are used to test large solar panels at a fraction of the cost of continuous solar simulators. Before a solar simulator can be used, it must be monitored and classified to prove that it can provide consistent information on panel or even cell performance.

The SR-1901PT is ideal for classifying pulsed solar simulators. Compact and portable, it is easy to take to any measurement challenge and can be quickly set up and used. It operates with a convenient integral phototrigger. Running our DARWin SP Data Acquisition software, the SR-1901PT includes spectral match reports for AM1.5. All scans are saved as ASCII files for easy use with most 3rd party software programs for additional data analysis.

Specifications of Spectroradiometers for Classifying Solar Simulators

Model

SR-3501

SR-1901

SR-1901PT

Spectral Range

280–2500nm

280–1900nm

280–1900nm

Spectral Resolution

4nm @ 280-1000nm

9.5nm @ 1500nm

7nm @ 2100nm

4nm @ 280-1000nm

10nm @ 1000-1900nm

4nm @ 280-1000nm

10nm @ 1000-1900nm

Sampling Interval

Data output in 1nm increments;

2221 channels reported

Data output in 1nm increments;

2221 channels reported

Data output in 1nm increments;

2221 channels reported

Si Photodiode Detector

512 element Si array (280–1000nm)

512 element Si array (280–1000nm)

512 element Si array (280–1000nm)

InGaAs Photodiode Detectors (TE-cooled)

256 element extended wavelength array (970–1900nm)

256 element extended wavelength array (1900-2500nm)

256 element extended wavelength array (970–1900nm)

256 element extended wavelength array (970–1900nm)

Suggested FOV Options

Right angle diffuser with fiberoptic, integrating sphere

Right angle diffuser with fiberoptic, integrating sphere

Right angle diffuser with fiberoptic, integrating sphere

Calibration

Factory calibrated to NIST traceable irradiance source

Factory calibrated to NIST traceable irradiance source

Factory calibrated to NIST traceable irradiance source

Integration Time

1 -1000 ms

1 -1000 ms

1 -1000 ms

Wavelength Reproducibility

0.1nm

0.1nm

0.1nm

Wavelength Accuracy

±0.5 bandwidth

±0.5 bandwidth

±0.5 bandwidth

Communications interface

USB or Class I Bluetooth– laptop or PDA compatible

USB or Class I Bluetooth– laptop or PDA compatible

USB or Class I Bluetooth– laptop or PDA compatible

Size

8.5” x 11” x 3.5”

22x28x9 cm

8.5” x 11” x 3.5”

22x28x9 cm

8.5” x 11” x 3.5”

22x28x9 cm

A/D Converter

16 bit

16 bit

16 bit

Weight

7.5 lbs (3.4kg)

7.5 lbs (3.4kg)

7.5 lbs (3.4kg)

Power

7.5V, 23W

7.5V, 18W

7.5V, 15W

Spectral Match

AM0, AM1.5, AM 1.5 global tilt

AM0, AM1.5, AM 1.5 global tilt

AM0, AM1.5, AM 1.5 global tilt

TTL

Yes

Yes

Yes

Phototriggering

No

No

Yes

Accessories for Spectral Evolution instruments

Click on the image for more information.

Contact Probes
Contact Probes
SR-1901 and SR-1901PT
Leaf Clip
SR-1901 and SR-1901PT
Benchtop Reflectance Probe
SR-1901 and SR-1901PT
Pistol Grip
SR-1901 and SR-1901PT
R&T and Integrating Spheres
SR-1901 and SR-1901PT
Light Sources
SR-1901 and SR-1901PT
Straight and Right Angle Diffusers
SR-1901 and SR-1901PT
Field Of View (FOV) Lenses
SR-1901 and SR-1901PT
Fibre Optic Cables
Spectral Evolution Tablet
Rugged Tablet
SR-1901 and SR-1901PT
Backpack

Thank You

The form was submitted successfully. 

Product Enquiry

Please complete all required fields.

Topics







Datenschutzeinwilligung*