Short Description
Spectral Evolution’s range of field-portable spectroradiometer bundles set the standard in precision, reliability and portability for spectral radiance, irradiance and reflectance measurements in the range from 320-2500nm. The all-solid-state design has no moving parts and features a silicon array for the UV-VIS-NIR band, with either one or two InGaAs detector arrays for the SWIR band. For the highest sensitivity, the detector arrays are thermoelectrically (TE) cooled.
Key Features
- Fast, full-spectrum UV-Vis-NIR measurements – 350-2500 nm with just one scan
- Superior reliability in the field – 100% diode array optics with no moving parts
- Freedom of movement with no cumbersome cables – Bluetooth connectivity
- Lithium-ion rechargeable batteries for field use
- Lightweight, rugged and field-proven
- Field switchable optics for varying target sizes and measurement modes
- Automatic exposure control and auto-shutter for error-free operation
- NIST- traceable calibration for spectral radiance & irradiance measurements
- Exclusive DARWin™ SP Data Acquisition and Analysis software for one-touch, full range spectroscopic analysis of samples
Available instruments of Remote Sensing Series
Models |
Full-Range, High Resolution & Most Portable |
|
PSR+ |
RS-3500 |
RS-8800 |
Spectral Range |
350-2500 nm |
Spectral Resolution |
2.8 nm @ 700 nm
8 nm @ 1500 nm
6 nm @ 2100 nm
|
2.8 nm @ 700 nm
8 nm @ 1500 nm
6 nm @ 2100 nm |
3 nm @ 700 nm
8 nm @ 1500 nm
6 nm @ 2100 nm |
Spectral Sampling |
1 nm increments, 2151 channels |
Spectral Accuracy |
±0.5 nm bandwidth, 0.1 nm reproducibility |
Detectors |
512-element Si array, two 256-element TE-cooled InGaAs arrays |
Calibration |
Spectral and radiometric calibration for radiance/irradiance measurements using NIST traceable sources. |
Dimensions (mm) |
215.9 x 292.1 x 82.5 |
215.9 x 304.8 x 88.9 |
314.9 x 228.6 x 381 |
Weight |
3.5 kg |
3.3 kg |
4.2 kg |
Models |
Full-Range, Highest Resolution & Sensitivity |
|
NaturaSpecTM |
NaturaSpecTM Ultra |
Spectral Range |
350-2500 nm |
Spectral Resolution |
2.7 nm @ 700 nm
5.5 nm @ 1500 nm
5.8 nm @ 2100 nm |
1.5 nm @ 700 nm
3 nm @ 1500 nm
3.8 nm @ 2100 nm |
Spectral Sampling |
1 nm increments, 2151 channels |
Spectral Accuracy |
±0.5 nm bandwidth, 0.1 nm reproducibility |
Detectors |
1024-element UV-enhanced Si array, 512-element TE-cooled InGaAs array, 512-element extended TE-cooled InGaAs array |
Calibration |
Spectral and radiometric calibration for radiance/irradiance measurements using NIST traceable sources. |
Dimensions (mm) |
314.9 x 220.9 x 111.7 |
314.9 x 220.9 x 111.7 |
Weight |
5.5 kg |
5.5 kg |